LITHIUM BLUE Battery
MECHANICAL SPECIFICATIONS
Industry Reference | BCI: Low G24R DIN: Tall H6 JIS: D26L | |
Length A (in/mm) | 10.3 | 262 |
Width B (in/mm) | 6.9 | 175 |
Height C (in/mm) | 8.3 | 210 |
Total Height D (in/mm) | 8.3 | 210 |
Weight (lbs/kgs) | 25.3 | 11.5 |
Terminal* | ST 5/16 | |
Cell(s) | Prismatic 4S1P | |
Case Material | UL94-VO PBT/PC | |
IP Rating | 67 | |
Electrolyte | LiFePO4 |
*TERMINAL TORQUE: 8 to 10 Nm (5.9 to 7.4 ft-lb). DO NOT EXCEED 10 Nm (7.4 ft-lb)
FEATURES
BLUETOOTH APP
- State of Charge
- Voltage / Current
- Temperature ˚F/˚C
HIGH-CURRENT BMS
- Field replaceable fuse protection
BENEFITS
ENHANCED RUNTIME
- Double the high-current runtime of lead-acid battery
- Up to 100% usable capacity
- Up to 100% Depth of Discharge
EXTENDED SERVICE LIFE
- 10x the life of lead-acid battery (BCI-06)
- Unlimited Partial State of Charge cycles
- Energy throughput warranty
FAST CHARGING
- Up to 5x faster than new lead-acid batteries
- Up to 10x faster than aged lead-acid batteries
- 2x faster than C/2 rated lithium batteries
- Opportunity charge at 1C rate anytime, regardless of SoC
SURGE POWER
- Surge power for inverter chargers
- Up to 3C peak power discharge rate
- Up to 1C continuous discharge rate
HIGH-EFFICIENCY
- Up to 50% more energy efficient than a lead-acid battery
- Up to 98% round-trip efficiency
PARALLEL POWER
- Easy to parallel more capacity
- Linear scaling of charge, discharge and peak capacity
QUICK INSTALL
- Fast installation. No special tools
- Drop-in lead-acid replacement
RELIABLE AND SAFE
- LiFePO4 is safe
- Maintenance-free
- UL94 V0 flame retardant case and cover
- IP 67 rated
CERTIFIED QUALITY
Discover® manufacturing facilities are fully certified to ISO 9001/14001 and OSHA 18001 standards.
CERTIFICATION STANDARDS
- CE
- UN 38.3
ELECTRICAL SPECIFICATIONS
Open Circuit Voltage (V) | 12.8 | |
Charge Voltage (Bulk Vdc) | 13.8 – 14.2 | |
Max Absorption Voltage (U1 Vdc) | 13.8 | |
Float Voltage (U2 Vdc) | 13.6 | |
BMS Max. Voltage protection (Vdc) | 14.6 (Approximately) | |
Suggested Low Voltage Cutoff (Vdc) * | 12 | |
BMS Min. Voltage protection (Vdc) | 10.0 (Approximately) | |
Max. Continuous Charge Current (I Max. Adc) |
100 | |
Min. Finishing Charge Current (I Min. Adc) |
2%-3% C1 / Min. 200ma | |
Max Continuous Discharge Current (Adc) |
100 | |
Max. Peak Current (Adc) | 250 A RMS (2 sec) | |
Self Discharge (25°C / 77°F) | < 3% per month | |
Charge Temperature | Min: 0°C (32°F) | Max: 55°C (131°F) | |
Discharge Temperature | Min: -20°C (-4°F) | Max: 60°C (140°F) | |
Storage Temperature | Min: -10°C (14°F) | Max: 30°C (86°F) |
Electrical Specifications at 25°C.
CAUTION: Extra considerations must be given to depths of discharge, operating voltages and currents when designing systems for use at maximum operating temperatures.
CAUTION: Do not exceed maximum voltage at the battery terminals (Bulk Vdc)
*NOTE: 98% of battery capacity is delivered above 3Vpc (12V, 24V, 36V and 48V models)